Add to Cart
High Altitude Test Chamber high-low Temperature for Aerospace Product
Characteristic
| ★ top-performance water ring vacuum pump controls low pressure. | ★ Optional remote-assist service function and teaching CDs. |
| ★Optonal APP mobility control | ★ Optional network video monitoring and data synchronization |
| ★ The Chambe is Fashion designed for modularity construction | ★ Automatic water supply with Ultrapure filter devices water shortage reminder function |
| ★ 7" colour touch clearly show screen display and 32 bit control system; interfce Ethernet and USB | ★ Automatic reminder of equipment maintenance plans and software of recording malfunction |
| ★ Built-in radiation shield ensures temperature homogeneity in low air pressure. | ★ top-performance servo refrigerating control technology: energy saving and fast heating/cooling rate |
| ★ Software functions: intelligent power-recovery restoration, auto-connect on memory and auto-reset restart. | ★ Unique operation mode: make testing area's temperature back ro room temperature after tests are finished |
| ★ Special protection design for overheat, powersupply abnormity,overload ,overvoltage, component malfunction monitoring |
Specification
| Temperature Chambers Climate Chambers | ETQ7025 | ETQ7050 | ETQ7100 | ETQ7200 |
| ECQ7025 | ECQ7050 | ECQ7100 | ECQ7200 | |
| Test Space Volume (L) | 250 | 500 | 1000 | 2000 |
| Temp. Test Parameters: | ||||
| Temp. Range (℃) | -70~+150 | |||
| Temp.Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
| Temp. Homogeneity (℃) | ±0.5 ~ ±2.0 (Atmospheric Pressure No Load) | |||
| Temp. Accuracy (℃) | ±2.0 (Atmospheric Pressure No Load) | |||
| Heat Up Time (min) (+20℃ to~150℃) | 60 | 60 | 50 | 60 |
| Cooling Down Time (min) (+20℃ to~60℃) | 90 | 80 | 60 | 80 |
| Pressure Range (Kpa) | Atmospheric Pressure~ 1.0 Atmospheric Pressure ~ 0.5 | |||
| Pressure Accuracy (Kpa) | ±2.0 (Atmospheric Pressure~ 40Kpa);±5%(40KPa~4KPa);±0.1(4KPa~1KPa) | |||
| Pressure Release Time (min) | 45(Atmospheric Pressure→1KPa) | |||
| Rapid Release of Pressure Function (Optional) | Pressure Release Range:75.2KPa →18.8KPa; Pressure Release Time:15sec | |||
| Climate Test Parameters for ECQ series: | ||||
| Temp. Range (℃) | +10 ~ +95 | |||
| Temp. Constancy (℃) | ±1.0 ~ ±0.8 (Atmospheric Pressure No Load) | |||
| Temp. Homogeneity (℃) | ±1.0 ~ ±2.0 (Atmospheric Pressure No Load) | |||
| Humid. Range (%RH) | (10) 20 ~ 98 (Atmospheric Pressure No Load) | |||
| Humid. Constancy (%RH) | ±1.0 - ±3.0 (Atmospheric Pressure No Load) | |||
| Test Space Dimension (mm) | 600W×600D×700H | 800W*700D*900H | 1000W×1000D×1000H | 1400W*1200D*1200H |
| External Dimension (mm) | 1000W×1800D×1800H | 1500W*2750D*1900H | 1400W×3250D×2000H | 1810W*3710D*2310H |
| Power | AC380V±10%,50HZ,3/N/PE | |||
| Cooling Methods | Water-Cooled | |||
| Options | Standard Version |
| ★ APP for mobility management | ★ 1 Set testing electrode |
| ★ Independent sensors for specimen protection (NE60519-2.1993) | ★ Electronic temperature and humidity sensors |
| ★ 1 Entry port Φ50mm | |
| ★ Nitrogen gas auxiliary device | |
| ★ Spare parts package | |
| ★ E-management and cyber-software | |
| ★ Rapid release of pressure device | |
| ★ Video monitor system | |
| ★ Rapid recovered pressure device |
