| ☆ Homogenous temperature linear changing rates: 5℃/min, 10℃/min | ☆ Optional remote-assist service function and teaching CDs. | 
| ☆ Dry air blowing system prevents specimen's surfaces from dewing in rapid temperature change | ☆ Intelligent and high-performance servo refrigerating control technology: energy saving and rapid heating/cooling rate | 
| ☆ 4 load power outlets for specimens with programmable control for protection | ☆ Unique operation mode: make testing area's temperature back ro room temperature after tests are finished | 
| ☆ Special air circulation system inside ensures testing accurancy | ☆ Optonal APP mobility management | 
| ☆ Desig with independent sensors to prevent specimens from damages caused by dewing, overheat, breezeless and smog | ☆ Automatic water supply with ultrapure filter devices; water shortage reminder function(ECS series) | 
| ☆ Special anti-condensation structures design to avoid misjudgment and improve testing accuracy in climate testing | ☆ Strong control abilities of extreme-low humidity range 20℃/10% R.H..(ECS Series) | 
|  			 Model  			 |  			 			 EC4018  			 |  			 			 EC7018  			 |  			 			 EC4034  			 |  			 			 EC7034  			 |  			 			 EC4060  			 |  			 			 EC7060  			 |  			 			 EC4100  			 |  			 			 EC7100  			 |  			EC4150 |  			 EC7150  			 |  		
|  			 Test Space Volume(L)  			 |  			 			 190  			 |  			 			 335  			 |  			 			 600  			 |  			 			 990  			 |  			 			 1540  			 |  		|||||
|  			 Temp Test Parameters:  			 |  		||||||||||
|  			 Temp. Range (℃)  			 |  			-42/+180 | -72/+180 | -42/+180 | -72/+180 | -45/+180 | -72/+180 | -45/+180 | -73/+180 | -42/+180 | -73/+180 | 
|  			 Temp. Constancy (℃)  			 |  			 			 
 ±0.1-±0.5  |  		|||||||||
|  			 Temp. Homogeneity (℃)  			 |  			 			 ±0.5-±2.0  			 |  		|||||||||
|  			 Heating Rate (℃/min)  			 |  			 			 4.0  			 |  			 			 4.0  			 |  			 			 3.2  			 |  			 			 3.0  			 |  			 			 4.0  			 |  			 			 4.0  			 |  			 			 4.0  			 |  			 			 4.0  			 |  			 			 3.5  			 |  			3.5 | 
|  			 Cooling Rate (℃/min)  			 |  			 			 4.0  			 |  			 			 3.0  			 |  			 			 4.0  			 |  			 			 3.0  			 |  			 			 3.0  			 |  			 			 2.5  			 |  			 			 3.0  			 |  			 			 2.5  			 |  			 			 2.5  			 |  			2.3 | 
|  			 Temp. Max. Thermal   			Compensation (W)  			 |  			 			 2800  			 |  			 			 1500  			 |  			 			 2800  			 |  			 			 1500  			 |  			 			 1500  			 |  			 			 2500  			 |  			 			 4500  			 |  			 			 3000  			 |  			4200 | 3000 | 
|  			 Climate Test Parameters:  			 |  		||||||||||
|  			 Dewpoint Temp. Range (℃)  			 |  			 			 +4(-3)-+94   			10-98   			±1.0-±3   			±0.1-±0.3   			±0.5-±2.0  			 |  		|||||||||
|  			 Humid. Range (%RH)  			 |  		||||||||||
|  			 Humid.Constancy (%RH)  			 |  		||||||||||
|  			 Temp. Constancy (℃)  			 |  		||||||||||
|  			 Temp. Homogeneity (℃)  			 |  		||||||||||
|  			 Temp and Humid Max.Thermal Compensation (W)  			 |  			 			 400  			 |  			 			 400  			 |  			 			 400  			 |  			 			 400  			 |  			 			 500  			 |  			 			 500  			 |  			 			 500  			 |  			 			 500  			 |  			 			 500  			 |  			 			 500  			 |  		
|  			 Power  			 |  			AC380V±10%,50HZ,3/N/PE | |||||||||
| Optional Accessories: | Standard Version: | 
|  			 • Independent sensors for specimen protection(NE60519-2.1993)   			• 1 Entry port Φ100mm 
  |  			• 3 Power outlets for specimens • Left and right entry ports Φ50mm • Silicon Stoppers for entry ports • 2 Stainless steel shelves • 1 Water tank with 20L • 1 Water filter  |